Twin RRU Power Supply | PSU-1200W-48-x | |||
|
Overview
Communication Components, Inc. Twin AC/DC RRU Power Supply provides a Universal AC Power alternative to power most –48 VDC Remote Radio Heads and other auxiliary outdoor equipment operating on –48VDC. The RRU Power Supply is a highly efficient convection cooled power source and as such does not require any internal or external fans for normal operation. The heatsink is integrated into the Power Supply housing and provides adequate convection cooling in outdoor ambient environments. The Power Supply enclosure and input and output connectors are completely weather sealed making it suitable for outdoor deployment in all environmental conditions. High reliability and high efficiency make the Twin AC/DC RRU Power Supply an ideal solution for both indoor and outdoor AC powered applications. Technical Description: The Twin Universal AC to –48 VDC RRU Power Supply provides a single -54.5 VDC Nominal output at a load of up to 24 ADC average, 32 ADC peak or Dual –54.5 VDC nominal outputs at loads of up to 14 ADC average, 16 ADC peak per output continuously. The input voltage can vary from 85 to 265VAC (47-63 Hz) while maintaining continuous operation under all rated load conditions. |
Electrical Specification
General Characteristics | PSU-1200W-48-N | PSU-1200W-48-E |
AC Input (47 - 63 Hz) | 85 - 265 VAC × 2 | |
Input Current per PSU | 17.6A (100 VAC), 8.8A (200VAC) | |
Inrush Current per PSU | 40A peak typical (100 VAC), 20A peak typical (200 VAC) | |
Recommended Breaker Size* | Dual pole 20A @ 110VAC / 10A @ 220VAC (not ganged) | |
Output Voltage | -48.0 VDC nominal, -54.5 maximum (absolute) | |
Output Current | 24.0 ADC avg/32.0 ADC peak | 14.0 ADC x 2 avg/16.0 ADC x 2 peak |
Power Factor | 0.95 minimum | |
Ripple and Noise | 4 V p-p | |
Overcurrent Protection | 105 - 140% (Auto Recovery) | |
Efficiency | 88% typical (at 70% rated load) / >90% (at 100% rated load) | |
Overvoltage Protection | 60 - 69.6 VDC typical (Auto Recovery) | |
Power on signal | Relay contact closure | |
Withstanding Voltage | Input to Output 3 KVAC, Input to Baseplate 2.5 KVAC, Output to Baseplate 1.5 KVAC | |
*Refer to local code in order to confirm the required breaker based upon our maximum peak current requirement |
Mechanical Specification
AC Input Connection* | 2 x IP67 rated Amphenol 3 pin C10 Series (not included). |
PSU-1200W-48-N DC Output Connection | 1 x IP55 rated, 8 AWG, 2 Wire Outdoor Cable w/ exposed pigtails. Compatible w/ Nokia connector 474283A (Amphenol C10-748591-Z2S) or similar. |
PSU-1200W-48-E DC Output Connection | 2 x IP55 rated 12AWG 2 Wire Outdoor Cable with exposed pigtails. |
Alarm Connection* | 2 x IP67 rated Amphenol 4 pin C09131G100 Series (not included) |
Pin 1 - Normally Closed | |
Pin 2 - Common | |
*Contact closure - Normal Operation; Contact break - Module Failure (No DC Output, Overcurrent, Over/Under Voltage, Overtemp, AC Failure) | |
Cooling Required | Convection via integral heatsink |
Dimensions (L x W x H) | 14.000 × 6.000 × 8.400 in. (355.6 × 152.4 × 213.4 mm) |
Weight | 23.3 lbs. (10.6 kg) |
*AC and Alarm Cables sold separately, 2 each required per twin PSU, available in multiple lengths, consult Parts & Accessories section below for part numbers. |
PSU-1200W-48-x Twin RRU AC/DC Power Supply Render | ||
PSU-1200W-48-x Twin RRU AC/DC Power Supply Outline Drawing, Nokia output cable shown. DC termination is two wire pigtail, connector shown is not included. |
Parts & Accessories
PSU-1200W-48-N | Twin RRU AC/DC Power Supply with Single DC Output for Nokia (1200W, -48 VDC) Note: Requires two (2) AC input cables that are not included see below for options. Available in 9 foot or 35 foot lengths. |
PSU-1200W-48-E | Twin RRU AC/DC Power Supply with Twin DC Output for Ericsson (2 x 700W, -48 VDC) Note: Requires two (2) AC input cables that are not included see below for options. Available in 9 foot or 35 foot lengths. |
PSU-1200W-48-N-K9 | PSU-1200W-48-N Kit, Including two 9 ft alarm cables (PSU-700W-ALC-9FT) and two 9 ft. AC cables (PSU-700W-ACC-9FT) and one 1200W power supply (PSU-1200W-48-N) |
PSU-1200W-48-N-K35 | PSU-1200W-48-N Kit, Including two 9 ft alarm cables (PSU-700W-ALC-9FT) and two 35 ft. AC cables (PSU-700W-ACC-35FT) and one 1200W power supply (PSU-1200W-48-N) |
PSU-1200W-48-E-K9 | PSU-1200W-48-N Kit, Including two 9 ft alarm cables (PSU-700W-ALC-9FT) and two 9 ft. AC cables (PSU-700W-ACC-9FT) and one 1200W power supply (PSU-1200W-48-E) |
PSU-1200W-48-E-K35 | PSU-1200W-48-N Kit, Including two 9 ft alarm cables (PSU-700W-ALC-9FT) and two 35 ft. AC cables (PSU-700W-ACC-35FT) and one 1200W power supply (PSU-1200W-48-E) |
PSU-700W-ALC-9FT | Alarm Cable, 9 Foot |
PSU-700W-ACC-9FT | AC Input Cable, 9 Foot (Wire Size - 12 AWG) |
PSU-700W-ACC-35FT | AC Input Cable, 35 Foot (Wire Size - 12 AWG) |
PSU-1200W-48-PMK | Pole Mounting Kit (for Twin RRU PSU) |
|