Single Band 4T4R n77 ORU | ORU-N77-Z08-2 |
|||
|
Overview
CCI's n77 Band 5G enabled ORAN Radio Unit (ORU) is compliant with the ORAN interface specifications supporting the 7.2x split network configuration and supports Open Radio Access Network (ORAN) interface. The RU comes equipped with two 10G eCPRI optical interface port to communicate with the Distributed Unit (DU) for fronthaul network interfacing. This compact ORU provides a standard open interface to other ORAN compliant vendor CU/DU, EMS, 5GC, and OSS products. Furthermore, it also supports the specifications set out in 3GPP Release 15.
|
Electrical Specification
RF Parameters | n77 Band |
3GPP Band | n77 |
DL/UL Frequency Range | 3800 - 3900 MHz |
DL/UL Branches | 4T4R |
Antenna Ports | 4 |
Tx Monitor Ports Coupling Factor | -40 ±0.7 dB |
Max IBW | 100 MHz |
Max Occupied BW | 100 MHz |
NR Carrier Bandwidth | 100 MHz |
DL/UL Modulation | ≤256QAM |
Output Power | 46 dBm per port max, 52 dBm in total |
Number of Carriers | 1 |
General Characteristics | ||
Voltage Range | -40.5 VDC to -58.5 VDC | |
RAT | NR | |
Duplex | TDD | |
SCS | 30 KHz | |
RET | AISG 2.0 with RS485 option only | |
External Alarm | 2 pairs | |
Front-haul interface | 7.2 Cat. A | |
SFP+ line rate | 10.3125 Gbps |
Front Panel & Logical Port Mapping
Front Panel | Description | Connector |
Antenna 0 | RF port connected to antenna. | 4.3-10 Female |
Antenna 1 | RF port connected to antenna. | 4.3-10 Female |
Antenna 2 | RF port connected to antenna. | 4.3-10 Female |
Antenna 3 | RF port connected to antenna. | 4.3-10 Female |
External Alarm | External alarm ports can be connected to 2 pairs of alarm inputs | 14 pin Circular connector |
RET | Control signal and DC port connected to RET etc. | 8 pin Circular AISG connector |
OPT1 & OPT2 | Optical Ports | SFP+ |
-48 VDC power supply | Power supply DC input port | Power Connector |
Grounding | Radio Grounding Port | M6 Bolt |
LED Overlay
|
|||
LED Overlay |
Specification | Detail | Value |
Power Consumption | 100% Load @25 degree | 430 W typical, 500 W maximum |
25 degree with 50% Load | 273 W typical | |
25 degree with 30% Load | 212 W typical | |
25 degree with 10% Load | 105 W typical | |
ETSI 202 706 based average | 205.5 W typical | |
DL Performance | Nominal Output Power | 46 dBm maximum |
Power Accuracy in Normal Test Environment | -1 dB to 0.5 dB | |
Power Accuracy in Extreme Test Environment | -2.5 dB to 0.5 dB | |
EVM: QPSK | 17.5% maximum | |
EVM: 16QAM | 12.5% maximum | |
EVM:64QAM | 8.0% maximum | |
EVM: 256QAM | 3.5% maximum | |
UL Performance | NF in room temperature | 2.6 dB typical, 3.0 dB maximum |
NF in full temperature | 3.0 dB typical, 3.5 dB maximum | |
Main Function Features | Remote Electrical Tilt | Based on AISG2.0 protocol and o-ran-ald.yang model to communication with the external RET equipment |
Voltage Standing Wave Ratio Detection | Support VSWR detection for each RF port to check antenna connectivity, there are two types of VSWR alarms: Minor VSWR alarm, RU will keep radiating, the service would be degraded. Critical VSWR alarm, RU would shut off corresponding RF branch. |
|
External Alarm | Support external device supervision, RU would monitor external alarm port state and send notification to O-RU controller based on o-ran-externalio.yang model when input port state is changed (circuit from open to closed or circuit from closed to open). RU can also report external alarm to O-RU controller once input port circuit from open to closed via customized fault. |
|
Split Mode | Refer to Chapter 5 | |
PAP | Support PA protection functions, including the scenario: SFP port abnormal disconnect External Power supply abnormal Abnormal signal generated |
Standards & Compliance
RF Performance, BS TX & RX | 3GPP TS 38.104 V15.16.0, ETSI TS 138 104 V15.16.0 |
RF Performance, Conformance Testing | 3GPP TS 38.141-1 V15.16.0, ETSI TS 138 104 V15.16.0 |
EMC | ETSI EN 301 489-1 V2.2.3:2019, ETSI EN 301 489-50 V2.3.1:2021, 3GPP TS 37.113 V15.7.0:2019, 3GPP TS 38.113 V15.7.0:2019, CISPR 32, IEC 61000-4-3, IEC 61000-4-6, IEC 61000-4-4, IEC 61000-4-5 |
Environmental, Storage | EN 300 019-2-1 |
Environmental, Climatic and Mechanical Tests | EN 300 019-2-4 |
Environmental, Ingress Protection | JIS C0920 IPX5, JIS C0920 IP6X, IEC 60529 IPX5, IEC 60529 IP6X |
Environmental, Earthquake | Telcordia GR-63-CORE, Zone4 |
Environmental, Transportation | EN 300 019-2-2, IEC 60721-3-2, JIS Z0200:2003 |
Environmental, Altitude | JIS C 60068-2-13 |
Environmental, Miscellaneous | Telcordia GR-487-CORE |
ORAN Interface | ORAN WG4.CUS0 v02.00, ORAN WG4.MP.0 v02.00 |
RoHS | Directive 2011/65/EU and amendment 2015/863/EU |
Safety | IEC 60950-1, IEC 60950 -22, IEC 60825-1 , EN 50383/4/5 |
AISG | AISG 2.0 |
|